The wrong door makes the room work harder.
Look down at the freezer entrance. Frost on the threshold, water at the sweep, and a compressor that never seems to stop usually start at the opening.
A forklift lane cycled 300 times a shift needs a different door than a cooler someone walks into twice an hour. We match the door to the traffic, install it with the envelope, and service the parts that wear.



System
Cold storage doors
Match the door to the traffic
| Door type | Temp range | Size range | Where it fits |
|---|---|---|---|
| Sliding (manual or automatic) | -60°C to +50°C | 0.8 × 1.9 m to 4.4 × 8 m | Forklift lanes, high-cycle, wide openings |
| Hinged / swing | -45°C to +50°C | 0.4 × 0.4 m to 2.7 × 3 m | Foot traffic; single or double leaf; German STUV hinges |
| Two-way (to-and-fro) | Chilled / processing | 40mm leaf, vision panel | Hands-full traffic between processing zones; food-hygiene compliant |
| Speed / sectional overhead | Dock & high-cycle | Wind-rated 450 N/m² | Fast open/close to cut air exchange; space-saving |
| Clean-room / atmosphere | -45°C to +50°C | Custom | Sealed rooms, glass vision panel, 100% gas-tight |
| Dock seals & levelers | -30°C to +65°C | Trailer-matched | Loading bays — seal the trailer gap, kill the infiltration |
Every door uses a 100% polyurethane core with German STUV hardware. The listed sizes are standard ranges, not limits. The final door is built to the opening, the temperature, the wall system, and the way the traffic approaches it.
Where door failures start
- 01Heat where frost startsAt 0°F, warm moisture freezes first at the frame and threshold. Heater wire, a PU core, and continuous gaskets stop that path when they're installed and maintained right. A failed heater wire still needs service.
- 02Wear parts close byHinges, gaskets, sweeps, motors, closers, and controls wear because the door is doing its job. We stock them for the doors we install, so a small failure doesn't become a week with the opening propped up.
- 03Installed with the envelopeA door is a moving hole in an insulated wall. We coordinate its frame, threshold, heater wire, floor transition, and panel connection as one opening. Separate details done by separate crews are where leaks begin.
A sealed door still needs maintenance.
The door is tight on installation day. Then gaskets flatten, closers drift, sweeps tear, and heater wires fail quietly. The first visible signs are frost, water, a damaged threshold, or longer compressor run time.
The service schedule follows the traffic, not the calendar. We install every door we sell and back it with a maintenance plan. A high-cycle forklift opening gets checked more often than a walk-through door on a dry cooler.
Questions we answer every week
Should I use a sliding or hinged cold-storage door?
Choose by what passes through the opening. Forklifts and pallet jacks usually need a sliding door, because nothing swings into the lane. Add automatic operation when the cycle count is high. Foot traffic usually wants a hinged single- or double-leaf door: simple, and cheaper to maintain. Hands-full movement between processing zones fits a two-way door with a vision panel. If people keep propping a door open, the door doesn't fit the job.
Why does my freezer door ice up?
Warm, moist air reaches a cold frame, threshold, or gasket and freezes. Prevention starts with heater wire in the frame and threshold, a polyurethane core without an easy thermal bridge, and gaskets that close evenly. On an existing door, the heater wire has often failed or the gasket and sweep have flattened. Those are normal service items, not reasons to replace the whole door. The caveat is maintenance: even the right heated door ices when its seals are ignored.
What cold-storage doors do I need at a loading dock?
Three parts working together: a dock seal or shelter around the trailer, a low-temperature dock leveler that bridges the trailer floor without becoming a thermal bridge, and a sectional overhead door for the empty bay. The assembly is rated from -30°C to +65°C, so it works on the cold side and in direct summer heat. Trailer size, approach, wind exposure, and cycle count still have to be checked at the site.
What is a two-way cold-room door used for?
People or carts moving between processing zones with their hands full. A 40mm two-way leaf swings either direction, closes itself, and has a vision panel so traffic can see through the opening. It works between cutting, packing, and staging rooms where washdown and hygiene matter. It's not the door for a 0°F freezer or a forklift lane; those openings need a tighter insulated door matched to their traffic.
Products
See them in the catalogue →
ARM Doors · 140 AMDouble-leaf door with vision panesHinged40 mmStainless frame
ARM Doors · 140 AMSolid polyethylene doorHinged15 mm PE leafWindow
ARM Doors · 240 AMRefrigerated sliding doorSliding65 mmStainless frame
ARM Doors · 340 AMHinged doorHinged40 mmStainless frame
ARM Doors · 480 GVSliding door for overhead rail linesSliding80 mmNo threshold
ARM Doors · 480 LWTAutomatic freezer sliding doorSlidingAutomatic80 mm
ARM Doors · 480 LWTSliding door, heated frame & thresholdSliding100–120 mmHeated
ARM Doors · 480 TNAutomatic sliding doorSlidingAutomatic80 mm
ARM Doors · 480 TNDouble-leaf sliding doorSlidingDouble-leaf80 mm
ARM Doors · 480 TNSliding doorSliding65–80 mmNo threshold
ARM Doors · 480 TNSliding door for controlled-atmosphere roomsSliding80 mmClamped seal
ARM Doors · 500 TNHinged door, safe-exit lockHinged65–80 mmSafe-exit lock
ARM Doors · 500 TNHinged door for controlled-atmosphere roomsHinged65–80 mmLever latch
ARM Doors · 500 TNDouble-leaf hinged door for overhead rail linesHingedDouble-leaf80 mm
ARM Doors · 500 TNDouble-leaf hinged doorHingedDouble-leaf80 mm
ARM Doors · 604 LWTHinged door, heated frame & thresholdHinged100–120 mmHeated
Cryo SystemsClean-room doorSelf-closingSilicone sealStainless & aluminum
Cryo SystemsGlass door for cold roomsHeated frameLED light14–41°F
Cryo SystemsHinged doorHinged0.8–1.5 m wideSTUV hinges
Cryo SystemsDoor range: swing, sliding, overheadSwingSlidingOverhead
Cryo SystemsManual sliding doorSlidingManualAluminum frame
Cryo SystemsHinged door, single or doubleHinged100–150 mm0.8–1.5 m wide
Cryo SystemsSelf-closing doorSelf-closing100–150 mmKASON lock
Cryo SystemsSliding door with heated windowSlidingHeated windowSteel
Cryo SystemsDouble-leaf hinged door, forklift widthHingedDouble-leaf100–150 mm
Cryo SystemsAutomatic double-leaf sliding doorSlidingAutomaticDouble-leaf
Cryo SystemsTwo-way door with windowSelf-closingStainless frameWindow
Cryo SystemsUp-opening doorVertical liftAluminum railSchneider controls
Tell us what crosses the opening.
For a full room, start with the estimator. For one door, send the opening size, wall thickness, temperature, cycle count, and traffic, and we'll tell you which door fits.
Or call (201) 256-1231